General information
|
|
|
|
|
|
|
Product type designation
|
DQ 8x24VDC/2A HF
|
DQ 16x24VDC/0.5A HF
|
DQ 32x24VDC/0.5A HF
|
DQ 8x230 V AC/5 A ST (relay)
|
DQ 8x230 V AC/2A ST (triac)
|
|
Product function
|
|
|
|
|
|
|
|
Yes; I&M0 to I&M3
|
Yes; I&M0 to I&M3
|
Yes; I&M0 to I&M3
|
Yes; I&M0 to I&M3
|
Yes; I&M0 to I&M3
|
|
Operating mode
|
|
|
|
|
|
|
|
|
Yes
|
Yes
|
|
|
|
|
|
No
|
|
|
|
|
|
|
No
|
|
|
|
|
|
|
No
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
|
|
Supply voltage
|
|
|
|
|
|
|
Type of supply voltage
|
DC
|
DC
|
DC
|
DC
|
|
|
Rated value (DC)
|
24 V
|
24 V
|
24 V
|
24 V
|
|
|
Reverse polarity protection
|
|
Yes; through internal protection with 7 A per group
|
Yes; through internal protection with 7 A per group
|
|
|
|
Digital outputs
|
|
|
|
|
|
|
Type of digital output
|
Transistor
|
Transistor
|
Transistor
|
Relays
|
Triac
|
|
Number of digital outputs
|
8; > 60 ?C Number of simultaneously controllable outputs max. 8x 0.5 A, max. total current per group 2 A
|
|
32
|
8
|
8; > 60 ?C number of simultaneously controllable outputs max. 8x 0.25 A, max. total current 2 A
|
|
Current-sourcing
|
|
Yes
|
Yes
|
|
|
|
Digital outputs, parameterizable
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Short-circuit protection
|
|
Yes; Clocked electronically
|
Yes; Clocked electronically
|
|
|
|
Limitation of inductive shutdown voltage to
|
-17 V
|
L (-53 V)
|
L (-53 V)
|
|
|
|
Controlling a digital input
|
|
Yes
|
Yes
|
possible
|
|
|
Switching capacity of the outputs
|
|
|
|
|
|
|
|
2 A
|
0.5 A
|
0.5 A
|
|
2 A
|
|
|
10 W
|
5 W
|
5 W
|
1 500 W; 10 000 operating cycles
|
50 W
|
|
|
|
|
|
10x 58 W (25 000 operating cycles)
|
|
|
|
|
|
|
1x 58 W (25 000 operating cycles)
|
|
|
|
|
|
|
10x 58 W (25 000 operating cycles)
|
|
|
Load resistance range
|
|
|
|
|
|
|
|
12 ?
|
48 ?
|
48 ?
|
|
|
|
|
4 k?
|
12 k?
|
12 k?
|
|
|
|
Output voltage
|
|
|
|
|
|
|
|
DC
|
DC
|
DC
|
AC
|
AC
|
|
|
L (-0.8 V)
|
L (-0.8 V)
|
L (-0.8 V)
|
|
L1 (-1.5 V) at maximum output current; L1 (-8.5 V) at minimum output current
|
|
Output current
|
|
|
|
|
|
|
|
2 A
|
0.5 A
|
0.5 A
|
5 A
|
2 A
|
|
|
0.5 mA
|
0.5 mA
|
0.5 mA
|
0 A
|
2 mA
|
|
Output delay with resistive load
|
|
|
|
|
|
|
|
100 ?s
|
100 ?s
|
100 ?s
|
|
1 AC cycle
|
|
|
500 ?s
|
500 ?s
|
500 ?s
|
|
1 AC cycle
|
|
Parallel switching of two outputs
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
|
|
No
|
No
|
No
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Switching frequency
|
|
|
|
|
|
|
|
100 Hz
|
100 Hz
|
100 Hz
|
2 Hz
|
10 Hz
|
|
|
0.5 Hz; According to IEC 60947-5-1, DC-
|
0.5 Hz; According to IEC 60947-5-1, DC-
|
0.5 Hz; According to IEC 60947-5-1, DC-
|
0.5 Hz
|
0.5 Hz
|
|
|
10 Hz
|
10 Hz
|
10 Hz
|
2 Hz
|
1 Hz
|
|
Total current of the outputs
|
|
|
|
|
|
|
|
2 A; Note derating data in the manual
|
0.5 A; see additional description in the manual
|
0.5 A; see additional description in the manual
|
8 A; Note derating data in the manual
|
2 A; = Tmax; > 60 ?C number of simultaneously controllable outputs max. 8x 0.25 A, max. total current per group 2 A
|
|
|
8 A; Note derating data in the manual
|
4 A; see additional description in the manual
|
4 A; see additional description in the manual
|
8 A; Note derating data in the manual
|
2 A; = Tmax; > 60 ?C number of simultaneously controllable outputs max. 8x 0.25 A, max. total current per group 2 A
|
|
|
16 A; Note derating data in the manual
|
8 A; see additional description in the manual
|
16 A; see additional description in the manual
|
64 A; Note derating data in the manual
|
10 A; = Tmax; > 60 ?C number of simultaneously controllable outputs max. 8x 0.25 A, max. total current per group 2 A
|
|
Relay outputs
|
|
|
|
|
|
|
|
|
|
|
8
|
|
|
|
|
|
|
24 V
|
|
|
|
|
|
|
80 mA
|
|
|
|
|
|
|
With miniature circuit breaker with characteristic B for: cos φ 1.0: 600 A cos φ 0.5 ... 0.7: 900 A with 8 A Diazed fuse: 1000 A
|
|
|
|
|
|
|
No
|
|
|
|
|
|
|
5
|
5
|
|
|
|
|
|
4 000 000; see additional description in the manual
|
|
|
|
|
|
|
Yes; 250 V AC/5 A g.p.; 120 V AC TV-4 tungsten; A300, R300
|
|
|
Switching capacity of contacts
|
|
|
|
|
|
|
|
|
|
|
see additional description in the manual
|
|
|
|
|
|
|
see additional description in the manual
|
|
|
Triac outputs
|
|
|
|
|
|
|
|
|
|
|
|
5
|
|
Cable length
|
|
|
|
|
|
|
|
1 000 m
|
1 000 m
|
1 000 m
|
1 000 m
|
1 000 m
|
|
|
600 m
|
600 m
|
600 m
|
600 m
|
600 m
|
|
Isochronous mode
|
|
|
|
|
|
|
Isochronous operation (application synchronized up to terminal)
|
No
|
Yes
|
Yes
|
No
|
No
|
|
Execution and activation time (TCO), min.
|
|
70 ?s
|
70 ?s
|
|
|
|
Bus cycle time (TDP), min.
|
|
250 ?s
|
250 ?s
|
|
|
|
Interrupts/diagnostics/status information
|
|
|
|
|
|
|
Diagnostics function
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
|
Substitute values connectable
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Alarms
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
|
Diagnostic messages
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
No
|
|
|
No
|
Yes
|
Yes
|
No
|
No
|
|
|
Yes
|
Yes
|
Yes
|
No
|
No
|
|
|
|
Yes
|
Yes
|
|
|
|
|
No
|
|
|
|
No
|
|
Diagnostics indication LED
|
|
|
|
|
|
|
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
|
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
|
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
No
|
|
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
Yes; Green LED
|
|
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
No
|
No
|
|
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
Yes; Red LED
|
|
Potential separation
|
|
|
|
|
|
|
Potential separation channels
|
|
|
|
|
|
|
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
|
Isolation
|
|
|
|
|
|
|
Isolation tested with
|
707 V DC (type test)
|
707 V DC (type test)
|
707 V DC (type test)
|
Between the channels: 2 500 V DC; between the channels and backplane bus: 2 500 V DC; between L backplane bus 707 V DC (type test)
|
2500 V DC
|
|
Standards, approvals, certificates
|
|
|
|
|
|
|
Suitable for safety functions
|
No
|
|
|
No
|
No
|
|
Ambient conditions
|
|
|
|
|
|
|
Ambient temperature during operation
|
|
|
|
|
|
|
|
-40 ?C; = Tmin
|
-40 ?C; = Tmin
|
-40 ?C; = Tmin
|
-25 ?C; = Tmin
|
-40 ?C; = Tmin
|
|
|
70 ?C; = Tmax; > 60 ?C Number of simultaneously controllable outputs max. 8x 0.5 A, max. total current per group 2 A
|
70 ?C; = Tmax; see Derating BasedOn (e.g. manual), additionally Tmax > 60 ?C max. aggregate current 2 A per group
|
70 ?C; = Tmax; see Derating BasedOn (e.g. manual), additionally Tmax > 60 ?C max. aggregate current 2 A per group
|
60 ?C; = Tmax
|
70 ?C; = Tmax; > 60 ?C number of simultaneously controllable outputs max. 8x 0.25 A, max. total current 2 A
|
|
|
-40 ?C; = Tmin
|
|
|
-25 ?C; = Tmin
|
-40 ?C; = Tmin
|
|
|
40 ?C; = Tmax
|
|
|
40 ?C; = Tmax
|
40 ?C; = Tmax
|
|
Extended ambient conditions
|
|
|
|
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m
|