Supply voltage
|
|
|
|
|
|
Load voltage L
|
|
|
|
|
|
|
24 V
|
24 V
|
24 V
|
24 V
|
|
Input current
|
|
|
|
|
|
from load voltage L (without load), max.
|
60 mA
|
90 mA
|
80 mA
|
160 mA
|
|
from backplane bus 5 V DC, max.
|
40 mA
|
70 mA
|
80 mA
|
110 mA
|
|
Power loss
|
|
|
|
|
|
Power loss, typ.
|
6.8 W
|
5 W
|
4.9 W
|
6.6 W
|
|
Digital outputs
|
|
|
|
|
|
Number of digital outputs
|
8
|
8
|
|
32
|
|
Limitation of inductive shutdown voltage to
|
L (-48 V)
|
L (-45 V)
|
L (-53 V)
|
L (-53 V)
|
|
Switching capacity of the outputs
|
|
|
|
|
|
|
10 W
|
5 W
|
5 W
|
5 W
|
|
Load resistance range
|
|
|
|
|
|
|
12 ?
|
48 ?
|
48 ?
|
48 ?
|
|
|
4 k?
|
3 k?
|
4 k?
|
4 k?
|
|
Output voltage
|
|
|
|
|
|
|
L (-0.8 V)
|
L (-0.8 to -1.6 V)
|
L (-0.8 V)
|
L (-0.8 V)
|
|
Output current
|
|
|
|
|
|
|
2 A
|
0.5 A
|
0.5 A
|
0.5 A
|
|
|
5 mA
|
10 mA
|
5 mA
|
5 mA
|
|
|
2.4 A
|
0.6 A
|
0.6 A
|
0.6 A
|
|
|
5 mA
|
10 mA
|
5 mA
|
5 mA
|
|
|
2.4 A
|
0.6 A
|
0.6 A
|
0.6 A
|
|
|
5 mA
|
10 mA
|
5 mA
|
5 mA
|
|
|
0.5 mA
|
0.5 mA
|
0.5 mA
|
0.5 mA
|
|
Switching frequency
|
|
|
|
|
|
|
100 Hz
|
100 Hz
|
100 Hz
|
100 Hz
|
|
|
0.5 Hz
|
2 Hz
|
0.5 Hz
|
|
|
|
10 Hz
|
10 Hz
|
10 Hz
|
10 Hz
|
|
Total current of the outputs (per group)
|
|
|
|
|
|
horizontal installation
|
|
|
|
|
|
|
|
4 A
|
4 A
|
4 A
|
|
|
4 A
|
3 A
|
3 A
|
3 A
|
|
|
4 A
|
2.5 A; (without diode) & 1.5 A (with diode)
|
3 A
|
2 A
|
|
vertical installation
|
|
|
|
|
|
|
4 A
|
4 A
|
2 A
|
2 A
|
|
Cable length
|
|
|
|
|
|
|
1 000 m
|
1 000 m
|
1 000 m
|
1 000 m
|
|
|
600 m
|
600 m
|
600 m
|
600 m
|
|
Interrupts/diagnostics/status information
|
|
|
|
|
|
Diagnostic functions
|
No
|
Yes; Parameterizable
|
No
|
No
|
|
Alarms
|
|
|
|
|
|
|
No
|
Yes; Parameterizable
|
No
|
No
|
|
Potential separation
|
|
|
|
|
|
Potential separation digital outputs
|
|
|
|
|
|
|
Yes
|
|
Yes
|
Yes
|
|
|
4
|
8
|
8
|
8
|
|
|
Yes; Optocoupler
|
Yes; Optocoupler
|
Yes; Optocoupler
|
Yes; Optocoupler
|
|
Isolation
|
|
|
|
|
|
Isolation tested with
|
500 V DC
|
500 V DC
|
500 V DC
|
500 V DC
|
|
Standards, approvals, certificates
|
|
|
|
|
|
CE mark
|
Yes
|
Yes
|
Yes
|
Yes
|
|
UL approval
|
Yes; File E239877
|
Yes; File E239877
|
Yes; File E239877
|
Yes; File E239877
|
|
FM approval
|
Yes
|
Yes; CofC 3028431
|
Yes; CofC 3028431
|
Yes; CofC 3028431
|
|
RCM (formerly C-TICK)
|
|
Yes
|
Yes
|
Yes
|
|
KC approval
|
|
Yes
|
Yes
|
Yes
|
|
EAC (formerly Gost-R)
|
|
Yes
|
Yes
|
Yes
|
|
Railway application
|
|
|
|
|
|
|
No
|
|
|
|
|
|
No
|
Yes; T1 Category 1 Class A/B horizontal mounting position
|
Yes; T1 Category 1 Class A/B horizontal mounting position
|
Yes; T1 Category 1 Class A/B horizontal mounting position
|
|
Ambient conditions
|
|
|
|
|
|
Ambient temperature during operation
|
|
|
|
|
|
|
-25 ?C
|
-25 ?C; = Tmin
|
-25 ?C
|
-25 ?C; = Tmin
|
|
|
70 ?C; = Tmax; 60 ?C @ UL/cUL use
|
70 ?C; = Tmax; 60 ?C @ UL/cUL use
|
70 ?C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... 55 ?C (T1) or 60 ?C @ UL/ULhaz/ATEX/FM use applies
|
70 ?C; = Tmax; for use on railway vehicles according to EN50155, the rated temperature range -25 ... 55 ?C (T1) or 60 ?C @ UL/ULhaz/ATEX/FM use applies
|
|
Ambient temperature during storage/transportation
|
|
|
|
|
|
|
-40 ?C
|
|
-40 ?C
|
-40 ?C
|
|
|
70 ?C
|
|
70 ?C
|
70 ?C
|
|
Extended ambient conditions
|
|
|
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... 2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa ( 2000 m ... 3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa ( 3500 m ... 5000 m)
|
|
Relative humidity
|
|
|
|
|
|
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions)
|
|
Resistance
|
|
|
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
|
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
|
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
|
Connection method
|
|
|
|
|
|
required front connector
|
20-pin
|
20-pin
|
20-pin
|
40-pin
|
|
Dimensions
|
|
|
|
|
|
Width
|
40 mm
|
40 mm
|
40 mm
|
40 mm
|
|
Height
|
125 mm
|
125 mm
|
125 mm
|
125 mm
|
|
Depth
|
120 mm
|
120 mm
|
120 mm
|
120 mm
|
|
Weights
|
|
|
|
|
|
Weight, approx.
|
190 g
|
210 g
|
190 g
|
260 g
|